20
07610-003-61-42-U
To delime the machine, follow the steps below. The tank capacities of the machine
can be found in the Specifications section of this manual.
1. Remove rinse arms and place in sink with deliming solution.
2. Disconnect or turn off chemical feeder pumps.
3. Add deliming solution per chemical supplier’s instructions.
4. Close the door and turn the machine on in MANUAL mode.
5. Run the machine for the length of time recommended by the chemical supplier.
6. Flip the mode switch to AUTO to shut the unit off.
7. Open the door and step away for 5 minutes.
8. Inspect the inside of the machine. If the machine is not delimed, run again.
9.
When clean, drain and re-fill the machine.
10. Run two cycles in AUTO to remove residual deliming solution.
11.
Drain and re-fill the machine.
12. Flush rinse arms with water and replace.
This equipment is not recommended for use with deionized water or other aggressive
fluids. Use of deionized water or other aggressive fluids will result in corrosion and
failure of materials and components. Use of deionized water or other aggressive fluids
will void the manufacturer’s warranty.
DELIMING
Mode Switch
Power Switch
DELIME INSTRUCTIONS
OPERATION
Summary of Contents for TEMPSTAR LT
Page 35: ...07610 003 61 42 U 28 26 1 29 28 30 33 34 36 CONTROL BOX ASSEMBLY PARTS ...
Page 67: ...07610 003 61 42 U 60 PARTS VENTLESS SYSTEM ASSEMBLY ...
Page 75: ...07610 003 61 42 U 68 SCHEMATICS 208 230 V 50 60 HZ 1 PHASE ...
Page 76: ...69 07610 003 61 42 U SCHEMATICS 460 V 50 60 HZ 3 PHASE ...
Page 77: ...07610 003 61 42 U 70 SCHEMATICS LT NB 208 230 V 50 60 HZ 1 PHASE ...
Page 78: ...71 07610 003 61 42 U SCHEMATICS LT NB 460 V 50 60 HZ 3 PHASE ...
Page 79: ...07610 003 61 42 U 72 SCHEMATICS STEAM 208 230 V 50 60 HZ 1 3 PHASE ...
Page 80: ...73 07610 003 61 42 U SCHEMATICS SDI OPTIONS ...
Page 81: ...07610 003 61 42 U 74 SCHEMATICS DRAIN QUENCH OPTION ...