07610-003-61-42-U
6
Volts
Phase
Hz
Rinse Heater
Rating
Total Amps
Typical Electrical Circuit
208
1
50
12 kW at 240 V
71 A
90 A
208
1
50
14 kW at 240 V
78 A
100 A
230
1
50
12 kW at 240 V
78 A
100 A
230
1
50
14 kW at 240 V
86 A
110 A
TempStar
208
3
50
12 kW at 240 V
45 A
60 A
208
3
50
14 kW at 240 V
49 A
70 A
230
3
50
12 kW at 240 V
48 A
60 A
230
3
50
14 kW at 240 V
53 A
70 A
380
3
50
12 kW at 380 V
29A
40 A
380*
3
50
14 kW at 380 V
34A
45 A
415
3
50
12 kW at 415 V
26 A
35 A
415
3
50
14 kW at 415 V
29 A
40 A
440
3
50
12 kW at 460 V
21 A
30 A
440
3
50
14 kW at 460 V
25 A
35 A
208
1
60
12 kW at 240 V
69 A
90 A
208
1
60
14 kW at 240 V
76 A
100 A
230
1
60
12 kW at 240 V
76 A
100 A
230
1
60
14 kW at 240 V
84 A
110 A
208
3
60
12 kW at 240 V
43 A
60 AP
208
3
60
14 kW at 240 V
47 A
60 A
230
3
60
12 kW at 240 V
46 A
60 A
230
3
60
14 kW at 240 V
51 A
70 A
460
3
60
12 kW at 480 V
22 A
30 A
460
3
60
14 kW at 480 V
25 A
35 A
* This model is wired in a wye configuration for the heaters.
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice.
NOTE: Typical Electrical Circuit is based on:
1. 125% of the full amperage load of the machine.
2.
Typical fixed-trip circuit breaker sizes as listed in the NEC (Latest Edition).
NOTICE
i
Imbalanced
wild leg goes
to L3.
NOTICE
Imbalanced
wild leg goes
to L3.
NOTICE
Summary of Contents for TEMPSTAR LT
Page 35: ...07610 003 61 42 U 28 26 1 29 28 30 33 34 36 CONTROL BOX ASSEMBLY PARTS ...
Page 67: ...07610 003 61 42 U 60 PARTS VENTLESS SYSTEM ASSEMBLY ...
Page 75: ...07610 003 61 42 U 68 SCHEMATICS 208 230 V 50 60 HZ 1 PHASE ...
Page 76: ...69 07610 003 61 42 U SCHEMATICS 460 V 50 60 HZ 3 PHASE ...
Page 77: ...07610 003 61 42 U 70 SCHEMATICS LT NB 208 230 V 50 60 HZ 1 PHASE ...
Page 78: ...71 07610 003 61 42 U SCHEMATICS LT NB 460 V 50 60 HZ 3 PHASE ...
Page 79: ...07610 003 61 42 U 72 SCHEMATICS STEAM 208 230 V 50 60 HZ 1 3 PHASE ...
Page 80: ...73 07610 003 61 42 U SCHEMATICS SDI OPTIONS ...
Page 81: ...07610 003 61 42 U 74 SCHEMATICS DRAIN QUENCH OPTION ...