Installation manual: OASiS security system JA-82KRC-US   

19 / 21 

MKH51400

 

ABC

 

hot key for setting the entire system (all sections 
A, B & C)  

A

 

hot  key  for  setting  section  A  (e.g.  afternoon 
partial setting of the garage)  

B

 

in  an  unsplit  system

:  hot  key  for  setting 

sections A and B (e.g. partial night-setting of the 
garage and the ground floor). 

 

in  a  split  system

:  hot  key  for  setting  section  B 

(C is only set if both sections A and B are set)   

?

 

Display  of  triggered  detectors  (e.g.  open 
windows), fault details and PGX / PGY status.   

   

   

turning on the PGX output from the keypad  (the 
same effect as 

81) 

   

turning off the PGX output from the keypad (the 
same effect as 

80) 

 

Notes: 

  The  A  and  B  keys  only  have  a  function  if  partial  setting  or 

splitting are enabled. 

  The keys 

 and 

 

only control the PGX output if they have 

been programmed for it,  see 12.5. 

13.1.5. 

Functions beginning with the  

∗ 

∗ 

∗ 

∗ 

key 

The  following  functions  are  available  to  the  user  via  the 

keypad: 

1

 

sets the entire system (the same as key ABC)* 

2

 

sets section A (the same as key A)* 

3

 

sets A and B, or just B (the same as key B)* 

4

 

event  memory  recall  (key  4  scrolls  backwards)  –  the 
control panel records max. 255 of the latest events 

5

 

new Master Code/Card (

5 MC NC NC) 

6

 

access code/card programming (

6 MC nn NC) 

7

 

for  operation  while  under  duress  (should  be  entered 
before the access code to secretly signal distress) 

8

 

PGX control (ON/OFF = 

81/

80 or enter 

8 to trigger if 

a pulsed switching reaction is programmed)* 

9

 

PGY control (ON/OFF = 

91/

90 or enter 

9 to trigger if 

a pulsed switching reaction is programmed)* 

0

 

To  enter  Service  Mode  (

0  SC  –  factory  default  8080) 

or to enter maintenance mode (

0 MC – factory default 

1234) 

The

 

∗ 

functions  allow  the  system  to  be  operated  from  a  mobile  phone 

keypad (if the control panel is equipped with the relevant communicator).  

 

13.2.  Programming access codes and cards 

The  system  can  be  controlled  by  4-digit  codes  or  by  access 

cards,  of  the  types  PC-01  and  PC-02  (EM  UNIQUE  125kHz 
standard).  

  The control panel has 1 service, 1 master and 50 user codes.   

  Only a numerical code can be used as a service code (factory 

default 8080) – see the control panel programming section. 

 

The  master  code 

can  be  a  numerical  code  (factory  default 

1234) or an access card. Using this master code/card, other 
users’  codes  and  cards  can  be  programmed  or  erased.  The 
master code/card is usually used by the system administrator. 

  Each  user  from 

01  to  50

  can  have  a  numerical  code,  or  a 

card,  or  both  (factory  default:  all  user  codes  and  cards  from 
01 to 50 are erased). 

  If  a  user  has  both  a  code  and  a  card,  then  it  is  possible  to 

program whether both a code and card must be presented to 
the system for system access, or whether only one of them is 
required (see 12.37). 

  The  system  does  not  allow  the  same  code  or  card  to  be 

programmed  to  multiple  users.  (if  it  is  desired  to  move  a 
code/card  to  another  user,  the  card/code  has  to  be  erased 
from its current user first).  

  It is possible to display which code/card positions are already 

occupied in maintenance mode (see 13.4.1). 

  The most convenient way to  program codes and cards is by 

using a PC running OLink software. 

  The  control  panel  allows  a  maximum  of  10  unsuccessful 

attempts in a row to enter a valid code or card. If exceeded, a 
tamper alarm starts. 

 

 

 

13.2.1. 

Programming access codes and cards 

Abbreviation 

Name  

Number 

Sequence 

Notes 

SC 

Service  

5 NC NC

 

  Only programmable in Service Mode. 

 

NC

 = new code (must be entered twice) – a card cannot be used. 

  Factory-default service code: 

8080 

  This code can be changed but not erased. 

 

Example: 5 4567 4567 

MC 

Master  

5 MC NC NC 

  Only programmable if the system is totally unset (disarmed) 

 

MC

 = master code or card (factory default 

1234

)  

 

NC

 = new code or card entry – a numerical code has to be entered twice, but a 

card only presented once 

  Either a code or a card can be programmed as a master code (to have both is 

impossible).

 

  The Master Code can be changed but not erased. 

  The Master Code’s reaction is set/unset and it is assigned to all sections. 

  To reset the Master Code to the factory default 1234, enter 291 in Service Mode 

(this will only affect the Master Code). 

  To make handing over the system to the end user easier, we recommend 

programming the system card (provided with the control panel) to the master 
code. 

 

Example:  

5 1234 and then presenting the card to the keypad’s RFID reader 

UC 

User  

50 

6 MC nn NC

 

  Only programmable if the system is totally unset

 

 

 

MC

 = Master Code or card.  

 

nn

 = user code or card position from 01 to 50. 

 

NC

 = new code or card entry.  

  Factory default: all user codes and cards are erased. 

  Each user position can have both a card and a code programmed to it (by using 

the sequence 

6 MC nn NC twice) 

  Each user code can have its own reaction programmed by an installer in Service 

Mode, and with a split system, codes can be assigned to different sections.  

  Example: 

6 1234 12 4345 (code 4345 will be programmed to user position 12)

  

 

To erase codes/cards enter: 

6 MC nn 0000 

erases the code and the card in user position

 nn.

 

6 MC 00 UC 

erases the code UC (or card UC) if programmed to any user position.   

6 MC 00 0000 

erases all user codes and cards in user positions

 

01 to 50.  

Summary of Contents for JA-82KRC-US

Page 1: ...OASiS security system JA 82KRC US 1 21 MKH51400 JA 82KRC US OASiS Control panel installation manual This manual is valid for control panel JA 82KRC US The control panel can be configured by a PC runn...

Page 2: ...ible alarms 13 12 21 Wireless siren alarm enabled IW and EW 13 12 22 Auto bypass user approval via the key 13 12 23 Final door detectors 13 12 24 Partial setting arming or system splitting 14 12 25 Au...

Page 3: ...01 to 50 for wireless inputs o The control panel does not allow for the simultaneous connection of both a wired and a wireless input to the same address Connecting to a wired input automatically disab...

Page 4: ...r Maintenance modes 1 2 Optional system configurations In the European Union region follow the valid standards and rules especially series EN 501 xx The Oasis control panel complies with grade 2 The c...

Page 5: ...allel resistors see the diagram below o For wiring examples see the below diagram TAMPER SIREN ACTIVATION TAMPER ACTIVATION TAMPER ACTIVATION TAMPER ACTIVATION ACTIVATION DOOR 1 DOOR 2 DETECTOR 1 DETE...

Page 6: ...control panel for 1 second e g using a screwdriver This will enter enrollment mode on the control panel 4 Install batteries into the keypad not far from the control panel 5 The keypad generates a bee...

Page 7: ...nection to the control panel possibly due to excessive distance or it could be too close to the control panel closer than 2 meters is not permitted To re enroll a device first disconnect its battery T...

Page 8: ...multiple control panels in one UC or AC receiver 12 Control panel programming The most convenient way to program the system is to use a PC running OLink software The system can however also be progra...

Page 9: ...g Entrance delay beeps 35x 351 YES 350 NO YES Setting arming confirmation by wired siren chirp 36x 361 YES 360 NO NO IW terminal only Siren always sounds during audible alarms 37x 371 YES 370 NO YES N...

Page 10: ...the effect or SET A or SET AB C has the effect or SET ABC or UNSET ABC In a split system a keyfob button pair assigned to section A SET UNSET A B SET UNSET B C SET UNSET ABC 61 nn r s Code card react...

Page 11: ...alarm PG on excluding Panic Panic A PGX on Panic B PGY on 6 AC dropout PG on Fire PGX on dropout PGY on 7 ON OFF 8 2 seconds pulse The ON OFF and 2 second pulse functions can be controlled from the ke...

Page 12: ...ter code has no effect on other codes and cards Resets are recorded in the control panel memory and sent to the ARC if used Alarm Receiving Centre previously called a central monitoring station 12 12...

Page 13: ...Wireless siren alarm enabled IW and EW This setting is for enabling and disabling wireless sirens in the system 3 8 1 wireless sirens enabled 3 8 0 wireless sirens disabled Note This setting has no e...

Page 14: ...nset immediately after the user sets unsets the system Assigning wireless devices access codes and keyfobs to various sections of the system has no effect in this mode Partial setting is especially su...

Page 15: ...r or a JA 80V version XA64005 or higher is installed 12 32 Annual check notification This sequence enables the user and installer to be notified of the necessary time for an annual technical check 690...

Page 16: ...hard wired input terminals in the control panel or enrolled wireless devices r is the reaction index from 0 to 9 see Table 2 s is the section 1 A 2 B 3 C only has an effect if partial setting or syst...

Page 17: ...rd has a natural reaction i e r 1 then its reaction is set unset set etc the same as reaction r 9 in table 2 A code card can also have an alarm reaction designated to it similar to detectors Factory d...

Page 18: ...is stored in the non volatile memory of keypads so power disconnection will not erase any stored text Convenient text editing is possible using a PC running OLink software Besides device names keypad...

Page 19: ...codes and cards from 01 to 50 are erased If a user has both a code and a card then it is possible to program whether both a code and card must be presented to the system for system access or whether o...

Page 20: ...can be scrolled through with the A indicator showing whether a code is programmed or not and the B indicator showing whether a card is programmed or not 4 To exit this code card display mode press th...

Page 21: ...st wake it up Install an ordinary magnetic sensor to the entrance door wiring it to the keypad input so that opening the door wakes up the keypad and reports to the control panel Alternatively power t...

Reviews: