JA-14K(R) Security System Control Panel
10 / 72
MNX22101
2 System size
The control panel can be split into 4 sections (independently adjustable parts). Every device has its own
address (keypads, detectors, sirens) and has to be enrolled to a section. Authorisation to access some of the
defined sections has to be added to each user.
Sections can be linked to other sections (common section) to control them and their statuses together.
2.1 Configuration and splitting
The JA-14K(R) security system control panel is meant to be used for protecting small and medium premises
thanks to its range, dimensions and number of sections. A section is a part of the system to which devices
related to a protected area are assigned. Small premises may have one basic section (flat, garage, etc…) and in
this case all devices are assigned to the same section. Larger systems can have multiple sections (for instance
a family house, or an office building) and also its own
2
nd
level common section
(common hall, cellars, garages,
toilets etc…). Very important for the operation of such systems is setting the user’s authorisation to the lowest
control level of the very basic sections. A common section is set automatically when all basis sections are set.
Otherwise is unset.
Note: The
“cleaning lady” user with access to the whole premises common section can have only a virtual
section assigned (1st level) and it does not have to include any detectors. Unsetting this virtual section also
automatically unsets all the common premises sections (2nd level) where she can move.
2.2 System control
The system keypad is meant for basic system control . There can be multiple keypads used in the system and
each one of them can work according to its own settings. Any system section can be controlled from each
keypad.
Every keypad offers 4
functional buttons
for quick control. Each of them can be set for various functions such
as setting/unsetting, applicance control or calling emergency. It can also be used for section status indication or
PG output indication (it can indicate the active status by standard red LED or green LED – the function “PG
indicates inversely”). That’s why the function button can serve as an indicator for a magnetic contact placed on
a door to see if the door is open or closed. And one more purpose is as a “Common functional button” and by
this you can control several sections simultaneously. For how to configure it read the keypad’s installation
manual.
1 – status indicator; 2 – system indicator; 3 - LCD display
4 – keypad and RFID reader; 5 – functional buttons
Sections split into two levels
(1-common, 2,3,4-controlled
independently)
2nd level
(controlled)
1st level
(operated)