JA-14K(R) Security System Control Panel
23 / 72
MNX22101
Code
authorization
Type Description
ARC code
This code has the highest level of authorization to configure the system’s behaviour and
is exclusively allowed to perform the system unblock after a triggered alarm. It can enter
Service mode, access all tabs with options including ARC communication to which it can
deny access to a Service technician (Service code). As long as the “Administrator-
restricted Service/ARC right” parameter remains unchecked, the ARC code can control
all sections and PG outputs used in the system. This code enables to add more
Administrators and other users with a lower level of authorization assign them with
codes, RFID tags. It also has a permission to erase alarm and tamper alarm memory.
The number of ARC codes is limited only by remaining capacity of the control panel. It is
given position 2 and it cannot be changed. The default ARC code is 1000 and when the
EN profile is enabled then it’s 100010. The code cannot be erased.
Service code
(Service)
It can enter Service mode and configure the system’s behaviour. It has access to all tabs
with options including ARC communication unless the access is limited by the ARC
technician. As long as the “Administrator-restricted Service/ARC right” parameter remains
unchecked, the Service code can control all sections and PG outputs used in the system. It
can create a user with ARC permission, other Service technicians, Administrators and
other users with a lower level of authorization and assign them with access codes, RFID
tags. The number of Service codes is limited only by remaining capacity of the control
panel. It is given position 0 and it cannot be changed. The default Service code is 1010
and when the EN profile is enabled then it’s 101010. The code cannot be erased.
Administrator
(Main)
This code has always full access to all sections and is authorized to control all PG
outputs. The Administrator can create other Administrator and other codes with a lower
level of authorization and assign them with access to sections and PG outputs, access
codes, RFID tags. Has permission to erase the alarm memory. There can be only one
main Administrator code which can’t be erased. When “Administrator-restricted
Service/ARC right” is enabled, the administrator code must be authorized as to confirm
access. It is given position 1 and it cannot be changed. The default Administrator code is
1234 and when the EN profile is enabled then it’s 123456. The code cannot be erased.
Administrator
(Other)
Has access to sections selected by the main Administrator to which the other
Administrator can add new users with the same or lower level of authorization to control
sections and PG outputs, assign them with access codes, RFID tags. Has permission to
erase the alarm memory in assigned sections. When “Administrator-restricted Service/
ARC right” is enabled, the administrator code must be authorized as to confirm access.
The number of Administrator codes (other) is limited only by remaining capacity
of the control panel. There is no code set by the factory defaults.
User
This code has access to sections and PG control rights assigned by an Administrator.
Users can add/delete their RFID tags and change their telephone numbers. It has
permission to erase the alarm memory in assigned sections. Selected users may have
their access to sections limited by a schedule. The number of User codes is limited only
by remaining capacity of the control panel. There is no code set by the factory defaults.
The user doesn´t have permission to edit their own access code nor to erase it.
Set
This code is allowed only to set a designated section. Users with this level of
authorization are not allowed to change their code and are not allowed to erase the
alarm memory. The number of Set codes is limited only by remaining capacity of
the control panel. There is no code set by the factory defaults.
PG only
Allows the user to control programmable outputs with authorization only. This applies to
both switching on and off. Users with this level of authorization are not allowed to change
their code and are not allowed to erase the alarm memory. The number of PG only
codes is limited only by remaining capacity of the control panel. There is no code set by
the factory defaults.
Panic
This code is allowed only to trigger Panic alarm. A user of this code is not allowed
to change it or erase the alarm memory. The number of Panic codes is limited only by
remaining capacity of the control panel. There is no code set by the factory defaults.
Guard Code
This is a code for a security agency. This level of authorization allows to set the whole
system. However the guard code can unset the system only during alarm or after it as
long as the alarm memory is still active. A user of this code is not allowed to change it or
erase the alarm memory. The number of Guard codes is limited only by remaining
capacity of the control panel. There is no code set by the factory defaults.
Unblocking
code
This code is designated to unblock the system after System blocking by alarm. A user of
this code is not allowed to change it or erase the alarm memory. The number of
Unblocking codes is limited only by remaining capacity of the control panel. There is no
code set by the factory defaults.
Creating new users and the administration of their authorization level is done by N-Link software.