JA-14K(R) Security System Control Panel
38 / 72
MNX22101
In the case when setting the system is prevented, an “Unsuccessful setting“ event is triggered and indicated by
rapid flashing of the system indicator with a yellow colour on the keypads and also by their beeping,
and acoustically by an outdoor siren as well. Simultaneously it is reported to a specific user or to the system
administrator if the report “Unsuccessful setting” is enabled, see N-Link SW, Communication tab.
To cancel the indication of unsuccessful setting it is necessary to select in the keypad menu an option called
“Cancel warning indication” or if the “Default” system profile has been pre-set then by setting that section.
9.12 Overview table of Groups of Events reported to users
All events which are sent to up to 8 users are assigned to 5 basic groups not only to the ARC when
a supplementary GSM or PSTN communicator is connected. This means alarms reported by SMS and by a call.
Every single group can be assigned to users arbitrary. Users to whom a group will be assigned will be sent
reports from this group. When the basic settings of the groups are not enough then there are 2 special groups
which can be used. User defined groups. Events can be added to those groups and can be given to only
specific users.
Overview table:
Order
Event
Group
1
Setting
SMS about Setting / Unsetting (3)
2
Unsetting
SMS about Setting / Unsetting (3)
3
Partially setting
SMS about Setting / Unsetting (3)
4
30 minute mains fault
SMS alerts (1) / Alarm call (2)
5
Mains restored after 30 min
SMS alerts (1) / Alarm call (2)
6
Instant alarm
SMS alerts (1) / Alarm call (2)
7
Instant alarm cancelled
SMS alerts (1) / Alarm call (2)
8
Delay alarm
SMS alerts (1) / Alarm call (2)
9
Delay alarm cancelled
SMS alerts (1) / Alarm call (2)
10
Tamper alarm
SMS alerts (1) / Alarm call (2)
11
Tamper alarm cancelled
SMS alerts (1) / Alarm call (2)
12
Fire alarm
SMS alerts (1) / Alarm call (2)
13
Fire alarm cancelled
SMS alerts (1) / Alarm call (2)
14
Panic alarm
SMS alerts (1) / Alarm call (2)
15
Panic alarm cancelled
SMS alerts (1) / Alarm call (2)
16
Health troubles
SMS alerts (1) / Alarm call (2)
17
Flooding
SMS alerts (1) / Alarm call (2)
18
Code breaking attempt
SMS alerts (1) / Alarm call (2)
19
Set with active zone (when confirmation enabled)
SMS alerts (1) / Alarm call (2)
20
Section without movement
SMS alerts (1) / Alarm call (2)
21
Overheating activation
SMS alerts (1) / Alarm call (2)
22
Overheating deactivation
SMS alerts (1) / Alarm call (2)
23
Freezing activation
SMS alerts (1) / Alarm call (2)
24
Freezing deactivation
SMS alerts (1) / Alarm call (2)
25
System start (out of service mode)
Fault and service SMS (5)
26
Device low battery
Fault and service SMS (5)
27
Device battery OK
Fault and service SMS (5)
28
Fault (device, communicator)
Fault and service SMS (5)
29
Fault end
Fault and service SMS (5)
30
Service mode entry
Fault and service SMS (5)
31
Service mode left
Fault and service SMS (5)
32
Low BATTERY
Fault and service SMS (5)
33
BATTERY OK
Fault and service SMS (5)
34
ARC communication fault
Fault and service SMS (5)
35
ARC communication restored
Fault and service SMS (5)
36
RF jamming
Fault and service SMS (5)
37
RF jamming end
Fault and service SMS (5)
38
Low credit balance
Fault and service SMS (5)
The assignment of events distinguished by the system to groups is specified in the table. On occurrence of an