JABLOTRON
ALARMS
a.s.
Pod
Skalkou
4567/33
46601
Jablonec
n.
Nisou
Czech
Republic
www
.jablotron.com
||
|
JA-14K(R) Security System Control Panel
11 / 72
MNX22101
3 The JA-14K(R) control panel utility parameters
The very basic component of the JA-10 system is the JA-14K(R) control panel. Its basic parameters are
summarized in the table below:
Tab. 1
Feature / Type
JA-14K(R)
Note
Maximum number of devices
32
It is the sum of wireless
and BUS components
Maximum number of users
16+3
Maximum number of independent
sections (partitions)
4
Maximum number of programmable outputs
4
Maximum number of radio modules
3
IP LAN (Ethernet) communicator
Yes
GSM / GPRS communicator
No
Optional accessory
PSTN telephone communicator
No
Optional accessory
Recommended 12 V backup battery
Max. 2.6 Ah
Lead-acid battery
Maximum continuous current consumption available
for devices from the control panel
85 mA (with LAN)
125 mA (no LAN)
For a 12 h backup supply
from the recommended
battery, the figure takes
into account the internal
consumption of the
control panel
Maximum possible short-term current demand
1000 mA
Max. 5 min
BUS terminal
1+RJ connector
The RJ connector is only
used to connect the radio
module directly in the
control panel.
Maximum BUS cable length
500 m
3.1 Description of JA-14K(R) control panel
The JA-14K(R) control panel is designed for
small or medium-sized systems
with wireless communication.
The JA-14K control panel is equipped with a LAN communicator which can be connected to the Internet and
with the ability to send data to secure mass storage areas, the so-called cloud (images taken by PIR detectors
with a camera or photo verification cameras) or to the server of security agencies with technical equipment for
this data to be received. It is also able to provide remote access using N-Link software thanks to an internet
connection.
The control panel can by supplied with a JA-111R radio module pre-installed as a kit called the JA-14KR.
The control panel can also be equipped with a JA-190Y meant to be used with a GSM provider’s network or the
JA-190X supplementary telephone communicator to be connected to an analogue landline (e.g. PSTN) or to
simulated telephone lines. Those supplementary modules can be used for the usual event reporting and it also
serves as a backup communicator if the previously mentioned LAN communicator indicates a fault
(communication path failed) but they cannot be both used simultaneously (there is only one connector on the
PCB).