Copyright IXXAT Automation GmbH
FlexRay CCM Manual, Version 2.4
Appendix
23
Appendix
Technical specifications
The following data refers to the standard equipment of the device.
Dimensions:
158 mm x 140 mm x 36 mm (L x B x H)
Weight:
approx. 650 g
Housing material:
Aluminium
Working temperature range:
-40 °C to +70 °C
Storage temperature range:
-40 °C to +85 °C
Relative humidity
10 - 95 %, non-condensing
Power supply:
6,5 - 50 V DC (start-up voltage over entire
working temperature range)
6 - 50 V DC after start-up
Power consumption:
typically with 12 V 400 mA
Host system:
Freescale MPC866P 133MHz
64 MByte RAM
32 MByte Flash
FlexRay Communication Controller:
Freescale MFR 43x0 or
2x Freescale MFR 43x0
(see Orderingcode)
FlexRay Transceiver:
Philips TJA1080
FlexRay MC-System:
Freescale MC9S12DP256
12 kByte internal RAM
256 kByte Flash
CAN MC-Controller:
Freescale MC9S12DP256
12 kByte internal RAM
1 MByte external RAM
256 kByte Flash
CAN Transceiver high-speed:
Texas Instruments SN65HVD251
CAN Transceiver low-speed:
Philips TJA1054T
CAN bus terminal resistor:
none (high speed),
RTH=RTL=2.2 k
Ω
(low-speed)
CAN and FlexRay signal delay
due to galvanic isolation:
typically 27 ns
Isolation voltage:
50 V DC
Summary of Contents for FlexRay CCM/ FRC-EP150
Page 4: ......
Page 26: ...Copyright IXXAT Automation GmbH FlexRay CCM Manual Version 2 4 Appendix 26...
Page 27: ...Copyright IXXAT Automation GmbH FlexRay CCM Manual Version 2 4 Appendix 27...
Page 28: ...Copyright IXXAT Automation GmbH FlexRay CCM Manual Version 2 4 Appendix 28...
Page 29: ...Copyright IXXAT Automation GmbH FlexRay CCM Manual Version 2 4 Appendix 29...
Page 33: ......