Copyright IXXAT Automation GmbH
FlexRay CCM Manual, Version 2.4
Connections
13
Pin
Signal
1
2
3
4
5
6
7
8
1
CAN3/4-Low
2
CAN1/2-low
3, 6
Ground (CAN)
4
CAN3/4-High
5
Reserved
7
CAN1/2-high
8
CAN VBAT
Table 3-4: Pin assignment of the CAN connector
No bus terminal resistor is integrated for high-speed CAN ISO 11898-2. If a bus
terminal resistor is required, it must be connected to the cable or connector. Fle-
xRay instrument leads with integrated terminal resistor are available as accesso-
ries.
The two CAN busses CAN1/3 and CAN2/4 are isolated galvanically from each
other and from all other interfaces.
3.1.4
Power connector (6 - 50 V DC)
The FlexRay CCM is supplied with direct current voltage of 6 V to 50 V. The
power supply input is protected against pole reversal and overvoltage.
Pin
Signal
1
2
1
Supply v
2
Ground
Table 3-5: Pin assignment of the power connector