OCEANO RT2500S/RT5000S Series – User Guide
System:
RT8x1
Preventive Maintenance
Sub-system
:
Reference:
PM05
Page:
2/5
Subject: Testing after Closure
Frequency: after each closure
Duration:
30 minutes
Part 2 – Transmit and Receive operation
Step
Action
1.
Press ENTER to activate the acoustic transmission of the command sequence selected.
2.
End of procedure
Part 3 – Simple Ranging operation (with Telecommand)
Step
Action
1.
Choose the Ranging telecommand sequence (
ARM+ARM
).
2.
Proceed through step
1
(use
Other CMD
as command type) and go to step
2
.
The RT8x1 transmits successively two CAF pulses that are received and processed by
the TT801. The ranging information is displayed.
3.
End of procedure
Part 4 – Release operation
Step
Action
1.
Choose the
RELEASE
or
RELEASE with PINGER
code as the CMD code.
2.
Proceed through step
1
(use
Release
or
Release with Pinger
as command type) and
go to step
2
.
3.
Press
ENTER
to transmit the acoustic code through the transducer.
The acoustic transponder should drive the motor/hook mechanism. The
acknowledgement pulses transmitted by the RT8x1 are received and processed by the
TT801 Telecommand Transmitter that displays ranging information as well.
4.
When using RELEASE with PINGER command, the RT8x1 series swap automatically to
the PINGER ON mode for about 3 minutes. To stop pinging before the 3 minutes, it is
required to send the PINGER OFF command.
5.
End of procedure