OCEANO RT2500S/RT5000S Series – User Guide
Figure 18 – Pinger dialog box
In the
Pinger pulse
area, the texts
Combination N˚
,
Frequency (kHz)
or
Code N˚
as
well as the relevant windows are dynamically up-dated depending on the type of the
corresponding pulse. These windows contain:
•
In the M-FSK case: 24 reply codes comprised between 0 and 23
•
In the tonal case: 32 tonal frequencies from the
.PRB
file.
The value of the
Pinger repetition rate (base rate)
field is comprised between 1 and 31
by 1 s step.
VI.5.4
C
OMMAND
M
ENU
The
Status…
sub-routine transmits the command requesting transponder status through
serial link. Then, after receipt of transponder response, it will up-date the main dialogue
box of the programming module.
The
Address reading…
sub-routine transmits the command requesting transponder
status through serial link, for the single purpose of retrieving the address of the connected
transponder in order to directly aim at the connected transponder, in the main dialogue
box of the programming module.
The
Load
sub-routine transmits all the commands taken into account in this module, in
order to perform complete programming of the connected transponder (this function
transmits NMEA 0183 commands through serial link exclusively).
The
Release
sub-routine transmits an acoustic transponder order to the transponder.
The
Reset…
sub-routine transmits the acoustic reset command. This command is aimed
at loading in the transponder memory the reference file which was factory stored in the
EEPROM of the Transponder.
For safety considerations, a dialogue box will open to ask the operator to confirm the
operation.
Additional
information
Status
Transponder
Address
Reading
Transponder
Load
Release
Reset
MU–RT8x1–AN–001 Ed. M – September 2013