GAPS
-
User Guide
4.4.1.4
Configuring the Pressure Input
1.
Click on the
INSTALLATION > INPUTS
.
2.
Click on
Pressure
to have access to the pressure sensor parameters.
3.
In
Input
, select the
Port
between
Serial A, B, C, D
or
Ethernet A, B, C, D
.
4.
In
Protocol
, select the
Protocol
and the
Timeout
in the corresponding scrolling lists.
5.
In Protocol, enter an
Offset
in millibar for the pressure sensor.
6.
For a
Serial
link, enter the
Parity
,
Stopbits
,
Standard
and
Baudrate
.
7.
For an
Ethernet
link, enter the
Transport Layer
, possible
IP
and
Port
.
8.
Click on
OK
to validate your input data configuration and send this data to the GAPS.