GAPS
-
User Guide
9.3.6
C
ONTROLLING
D
ATA
A
CQUISITION USING I
X
BLUE
M
ULTILOGGER
iXblue Multilogger checks in real-time the consistency of several data streams carried by
different protocols (PHINS_STANDARD, POSTPROCESSING, NMEA ...). Erroneous data
are then detected in real-time and appropriate adjustments can be carried out immediately.
Repeater log
The repeater log is available in TCP connection on port 8210.
1.
Open iXblue Multilogger.
2.
Click on the general configuration button.
Set up the logging file and folder, session name, automatic log, date and hour format.
Set up the time out configuration, time stamping, segmentation options, log report.
Set up the display options and files lock. Click on
OK
.
3.
Click on one of the flow configuration button.
Set up the
Flow type
(
Serial
or
Ethernet
).
Set up the
Flow log name
,
Segmentation
and
Decimation
.
Select a
Protocol
:
PHINS_STANDARD
,
NMEA
,
ASCII
...
Select the
Operation
to run:
Check consistency
or
Decode and check
.
Set up the
Settings
and click on
OK
to validate, the flow button becomes:
152
MU-GAPS-AN-005-H - November 2019
Summary of Contents for GAPS
Page 1: ...GAPS Positioning System User Guide...
Page 2: ......
Page 22: ...GAPS User Guide Figure 7 HiSys hoisting system 22 MU GAPS AN 005 H November 2019...
Page 112: ...GAPS User Guide Figure 52 Mobile properties window 112 MU GAPS AN 005 H November 2019...
Page 228: ...PAGE INTENTIONALLY LEFT BLANK 228 MU GAPS AN 005 H November 2019 GAPS User Guide...
Page 229: ...GAPS User Guide L GAPS Antenna Mechanical Drawing MU GAPS AN 005 H November 2019 229...
Page 231: ...GAPS User Guide N GAPS BOX Mechanical Drawing MU GAPS AN 005 H November 2019 231...
Page 232: ...GAPS User Guide O Rackable GAPS BOX Mechanical Drawing 232 MU GAPS AN 005 H November 2019...