21
Ov
er
vie
w
Operational functions
Output functions
Ŷ$ODUPRXWSXWIXQFWLRQVHHSDJH
Enable or disable the output of the batch completion, STOP, Pre-STOP, interlock, diaphragm rupture detection,
pressure overload detection, and/or drive error detection functions which is preset to the Alarm OUT 1 and 2,
or the output of the volume proportional pulse which is preset only to the Alarm OUT 2. See the "Alarm OUT
(DIN connector)" paragraph on page 37 for wiring diagram.
Alarm OUT 1 (OUT 1) : Mechanical relay output (no voltage contact 1a×1 250VAC 3A, resistive load)
Alarm OUT 2 (OUT 2) : PhotoMOS relay output (no voltage contact 1a×1 24VAC/DC 0.1A, resistive load)
* If the batch completion output is enabled to the Alarm OUT 1 or 2 (or if the volume proportional pulse output
enabled only to the Alarm OUT 2), the other outputs (STOP, Pre-STOP, interlock, diaphragm rupture detec-
tion, pressure overload detection, and drive error detection) turn disabled in that Alarm OUT.
* The other outputs (STOP, Pre-STOP, interlock, diaphragm rupture detection, pressure overload detection, and
drive error detection) can be enabled together (to the Alarm OUT 1 or 2), sharing the same output signal. See
the controller display to tell which the signal it is.
:LWKHWKHIDFWRU\GHIDXOWVHWWLQJWKHUDQJHRIWKHYROXPHSURSRUWLRQDOSXOVHRXWSXWLV]DWWKHPLQ
ÀRZRIWKH]DWWKHPD[ÀRZUDWHRIWKHSXPS7KHPD[ÀRZUDWHLVPDQXDOO\UHGXFHGDV
shown below through the "Pump Max Rate" options in the "Other Features" menu.
Ŷ$QDORJRXWSXWIXQFWLRQVHHSDJH
7KHSXPSWUDQVPLWVWKHP$DQDORJVLJQDOLQSURSRUWLRQWRWKHSUHVHWÀRZUDWHVVHWSRLQWDQG
*
,IWKHDFWXDOÀRZKDVIDOOHQEHORZWKHPLQLPXPÀRZDWHDFKPRGHOVHHSDJHWKHDPSHUDJHJRHVGRZQWR
the 0L/H level.
* The amperage does not fall below 0mA or exceed 20mA at any setting of the set point 1 and 2.
20mA
SP.2
SP.1
4mA
0mA
SP.1
SP.2
MAX
0L/H
MIN
200Hz
1Hz
0Hz
7.5mL/H
7.5L/H
The max flow rate can be
DGMXVWHGZKLOHL]
,;%9ROXPHSURSRUWLRQDOSXOVHRXWSXWEHKDYLRXU