<n>
0
=
mute off
1
=
mute on
10.7
Set Real Time Clock +CCLK
Description:
This command set and gets the real time clock of the module. The time-zone set acts as additional information
to user.
Syntax:
AT+CCLK=<time>
Command
Possible Responses
AT+CCLK=<time>
OK
or
CME ERROR: <error>
AT+CCLK?
+CCLK: <time>
+CME ERROR: <err>
AT+CCLK=?
Defined Values
<time>
string type value; format is “yy/MM/dd,hh:mm:ss+TZ”, wherein characters indicates year, month, day, hour,
minutes, seconds.
TZ: Time zone information represented by two digits. The time zone information is optional; if it was entered it
is always accepted, but the display of TZ for query contains this information (in updated form) only if the
network supports the time zone information.