138
10.3
TE-TA Local Flow CIFC
Description:
This command is used to control the operation of the local flow control between TE and TA.
The <DCE_by_DTE> and <DTE_by_DCE> values must be equal.
Syntax:
AT+IFC=<DCE_by_DTE>,<DTE_by_DCE>
Command
Possible Responses
AT+IFC=<DCE_by_DTE>,<DT
E_by_DCE>
OK
AT+IFC=?
+IFC: (0-2),(0-2)
OK
AT+IFC?
+IFC: 0,0
OK
AT+IFC=2,2
Note: Set to flow control
OK
Defined Values
<DCE_by_DTE>
Specifies the method to be used by the DTE to control the flow of received data
from the module.
0
=
None. (Default)
1
=
XON/XOFF on transmitted data (XON/XOFF on transmit data); do
not pass XON/XOFF characters to the remote modem.
2
=
Circuit 133 (Ready for Receiving).
<DTE_by_DCE>
Specifies the method to be used by the module to control the flow of transmitted
data from the DTE.
0
=
None. (Default.)
1
=
XON/XOFF on received data.
2
=
CTS/RTS
10.4
Phone Activity CPAS