![Italkero Poster PE t1 30 Installation And Technical Manual Download Page 35](http://html1.mh-extra.com/html/italkero/poster-pe-t1-30/poster-pe-t1-30_installation-and-technical-manual_2094805035.webp)
ANOMALY
CAUSE
REMEDY
The room thermostat fails
to trigger
Adjust thermostat knob
Adjust the thermostat knob:
- Towards 7 to increase
- Towards 1 to decrease
Unfavourable appliance position
Change appliance position
Upper or lower grilles blocked
Clean / Free
Riders in wrong position
Adjust riders
The Timer fails to trip or
does not operate
Operating switch in wrong position
Position on “clock”
Power supply switch off
Reset and programme Timer
Thermostat bulb exited from seat
Position correctly
Room thermostat faulty
Replace
Timer faulty
Replace
No spark on ignition
Ignition/detection electrode unit
faulty, earthed or badly connected
Check / Replace
Flame control board fault
Check / Replace
The burner switches off while
operating
Not enough or irregular
gas pressure
Check /Adjust gas
Intake and outlet pipes badly fitted
Check / Remedy:
- pipe length
- appliance /pipe seal
Intake/Outlet diaphragms not fitted
Fit diaphragms
The appliance does not
heat enough
Gas/nozzle pressure inadequate
Check and adjust gas / Replace
Appliance output not suitable
for premises
Replace the appliance with a
more powerful one.
The centrifugal fan fails to start
Control board faulty
Replace
Motor faulty
Replace
The tangential fans fails to start
Air temperature below 50
∞
C
Check / wait for heating
Motor faulty
Replace
Control board faulty
Replace
Reduced hot air flow
Tangential fan faulty
Replace
Inflow/Outflow grilles blocked
Free
Fan dirty
Clean/Free
35
CUSTOMER SERVICE
Summary of Contents for Poster PE t1 30
Page 1: ......
Page 37: ...37 NOTE NOTE ...
Page 38: ...38 NOTE NOTE ...
Page 39: ......
Page 40: ...35200097 Rev 1 10 2006 ...
Page 41: ......
Page 47: ...user 7 CONVECTOR POSTER Fox PE GAS CONVECTOR TYPE C FOR HEATING ...
Page 56: ...user 35200097 Rev 1 10 2006 ...