Disassembly cover
- Disassembly the skirt
- Remove the cup (3)
- Unscrew the screw (2)
- Remove the outside skirt (1) completely
- To replace the skirt do the reversed sequence
34
CUSTOMER SERVICE
DISASSEMBLY & REASSEMBLY OF THE SKIRT
EVENTUAL ANOMALIES & REMEDIES
ANOMALY
CAUSE
REMEDY
Not proper injectors for the gas used
Use the proper injectors
Electrical plug out
Verified if the plug is inserted
The convector doesn’t start
Gas pressure not regulated
Regulated the pressure
Thermostat doesn’t work
Regulate the thermostat
Burned fuse
Replace
Processor control box (P.C.B assy)
Replace
High Atmospheric temperature
regular the atmospheric thermostat on 7
Air in the gas tube
Replace
Not a regular distance
between the electrode
Put them at the right distance
If the convector starts
Dirty injectors
Clean the injectors
Pressure switch absence
Verified/replace
-tubes ore not conform
-Pressure switch (check the cable)
-tubes (check if they ore clean)
-Centrifugal fan