2.3
Sales by Weight
1
Check that nothing is on the weigh platter.
•
Check that the ZERO indicator is lit.
•
If not, press the ZERO key.
2
Subtract the tare.
■
Weighing tare
•
Place the tare on the weigh platter. The tare weight will be
displayed.
•
Press the TARE key.
The displayed value will return to zero, and the NET
indicator will light.
■
Fixed tare weight
•
Enter the tare weight and press the TARE key.
s
Tare look-up key
•
Press the tare look-up (preset) key.
3
Enter the PLU.
■
PLU number entry
•
Enter the PLU number and press the PLU key.
■
PLU (preset) key
•
Press the preset key in which the PLU item data is set.
4
Weigh the item.
•
Place the item on the weigh platter.
5
Perform mark down operation if necessary.
•
Refer to page 20.
6
Print the label.
■
When not using the operator system
•
Press the PRINT key.
■
When using the operator system
•
Press the operator key.
ZERO
8
TARE
NET
TARE
Ex. Weight = 0.08 lb.
Ex. Access Tare #1
➔
ZERO
PLU
➔
5
0
3
Ex. PLU No. = 350
TARE
#1
Ex. Access PLU10
PLU10
PLU90
Ex. Access PLU90
➔
LOWER
PRESET
PLU10
PLU90
Ex. Operator = Susan
Susan