LUBRICATION & PERIODIC MAINTENANCE
73
Fuel filter should be replaced by ASSY.
It is impossible to disassemble and maintenance.
Air-bleeding Procedure
Air bleeding is not necessary.
NOTE: Normally, further air-bleeding is not required
due to electric fuel pump operating when start-
er switch in instrument panel is ON. If engine
will not start after several attempts, check fuel
pump fuses (see Electrical System) and then
proceed as necessary.
CAUTION: Fuel emitted from loosened in-
jection lines is under high pressure. Keep
hands and face away when the engine is
cranked. Clean all spilled fuel following air-
bleeding procedure (s).
Throttle Lever
FIG. 6-31:
The throttle lever should remain in the posi-
tion selected by the operator. Through normal use, fric-
tion against the lever may decrease, causing the lever to
move out of the selected position. Turn the adjusting nut
(1) as required to retain the throttle lever in the position
selected.
NOTE: Throttle lever friction adjustment nut is reached
by removing the steering column cover, and in-
strument panel.
In case lining is exchanged to parts, apply grease and
assemble is.
FIG. 6-30
1
FIG. 6-31