CHV180 series frequency inverter special for elevator Detailed function description
.63.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P7.06
Running state
display
selection
0x00FF
0~0x03FF
0x00FF
In the running state, CHV180 series inverters can display 5 parameters: running speed,
set speed, bus voltage, output voltage and output current.
The displayings of other parameters are determined by the function code. If Bit is 0, the
parameter will not be displayed; If Bit is 1, the parameter will be displayed. Press
》
/SHIFT to scroll through these parameters in right order. Setting function code P7.06,
binary numbers should be changed into hex numbers.
The display content corresponding to each bit of P7.06 is described in the following:
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
AI2
AI1
Output
terminal
state
Input
terminal
state
Output
torque
Output
power
Rotation
speed
Running
frequency
BIT15
BIT14
BIT13
BIT12
BIT11
BIT10
BIT9
BIT8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Pole
position
Torque
compensation
Note: I/O terminal state is displayed in decimal.
For details, please refer to
description of P7.19 and P7.20.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P7.07
Stop state
display
selection
0~0x01FF
0~0x01FF
0x00FF
P7.07 determines the display parameters in stop state. The setting method is similar with
P7.06.
The display content corresponding to each bit of P7.07 is described in the following
table: