CHV180 series frequency inverter special for elevator Detailed function description
.61.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P6.26
0~65536
0~65536
0
6.8 P7 Group –Human-Machine interface
Function
Code
Name
Description
Setting
Range
Factory
Setting
P7.00
User
password
0~65535
0~65535
0
The password protection function will be valid when it is set to be any nonzero data.
When P7.00 is set to be 00000, the user’s password set before will be cleared and the
password protection function will be disabled.
After the password has been set and becomes valid, the user can not access menu if
the user’s password is not correct. Only when a correct user’s password is input, the
user can see and modify the parameters. Please keep user’s password in mind.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P7.01
LCD language
selection
0: Chinese
1: English
0~1
0
P7.02
Parameter
copy
0: Invalid
1: Upload parameters to LCD
2: Download parameters from
LCD
0~2
0
P7.02 will take effect when LCD keypad is used.
1: All value of parameters will be uploaded from inverter to LCD keypad
2: All value of parameters will be downloaded from LCD keypad to inverter.
Note: When upload or download operation is completed; P7.02 will be set to 0
automatically. The function will be reserve temporary.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P7.03
QUICK/JOG
function
selection
0: Examine running
1: FDW/REV switching
0~1
0
QUICK/JOG is a multifunctional key, whose function can be defined by the value of
P7.03.