CHV180 series frequency inverter special for elevator Appendix D
.133.
Function
Code
Name
Description
Factory
Setting
Mod
ify
LCD Display
SPEED 6
P1.07
Multi-step speed 7 0.000~P0.02
0.000m/s
◎
MULTI-STEP
SPEED 7
P1.08
Start quadric
acceleration
0.001~10.000 m/s
3
0.350m/s
3
◎
START
QUADRIC
ACCEL
P1.09
Start acceleration 0.001~10.000 m/s
2
0.700m/s
2
◎
START
ACCEL
P1.10
Speed-down
quadric deceleration
0.001~10.000 m/s
3
0.350m/s
3
◎
SPEED-DOW
N QUADRIC
DECEL
P1.11
Deceleration
0.001~10.000 m/s
2
0.700m/s
2
◎
DECEL
P1.12
Stop quadric
deceleration
0.001~10.000 m/s
3
0.350m/s
3
◎
STOP
QUADRIC
DECEL
P1.13
Stop deceleration 0.001~10.000 m/s
2
0.700m/s
2
◎
STOP DECEL
P1.14
Start speed
0.000~0.250 m/s
0.000m/s
◎
START
SPEED
P1.15
Start holding time 0.0~5.0s
0.0s
◎
START
HOLDING
P1.16
Overhaul running
speed
0.000 m/s~P0.02
0.300m/s
◎
OVERHAUL
RUNNING
TIME
P1.17
Overhaul running
acceleration
0.001~10.000 m/s
2
1.000m/s
2
◎
OVERHAUL
RUNNING
ACCEL
P1.18
Overhaul running
deceleration
0.001~10.000 m/s
2
1.000m/s
2
◎
OVERHAUL
RUNNING
DECEL
P1.19
Motor autotuning
acceleration
0.001~10.000 m/s
2
0.600 m/s
2
◎
MOTOR
AUTOTUNIN
G ACCEL