CHV180 series frequency inverter special for elevator Appendix A
.115.
Function
Code
Name
Recommendation
setting
Remark
P1.05
Multi-step Speed 5 Normal low speed
P1.06
Multi-step Speed 6 Normal high speed 1
P1.07
Multi-step Speed 7 Normal high speed 2
P1.08
Start quadratic
acceleration
0.350m/s
P
3
P
Set by on-site debugging
P1.09
Start acceleration 0.700m/s
P
2
P
P1.10
Speed-down
quadratic
deceleration
0.350m/s
P
3
P
P1.11
Deceleration
0.700m/s
P
2
P
P1.12
Stop quadratic
deceleration
0.350m/s
P
3
P
P1.13
Stop deceleration 0.700m/s
P
2
P
P1.14
Start speed
0.000m/s
P1.15
Start speed holding
time
0.0s
P1.16
Overhaul running
speed
0.300m/s
P1.17
Overhaul running
acceleration
1.000 m/s
P
2
P
P1.18
Overhaul running
deceleration
1.000 m/s
P
2
P
P2.00
Motor type selection
Affirm the type of
motor
Set by tractor nameplate
P2.01
Tractive roller
diameter
Tractor nameplate
P2.02
Reduction ratio
Tractor nameplate
P2.03
Hoist rope hanging
ratio
Tractor nameplate
P2.04
Motor rated power Tractor nameplate
P2.05
Motor rated
frequency
Tractor nameplate