CHV180 series frequency inverter special for elevator Appendix D
.139.
Function
Code
Name
Description
Factory
Setting
Mod
ify
LCD Display
17: Contactor
feedback signal
18: Brake feedback
signal
19: Inverter enable
20:Forcing
deceleration stop
21~40: reversed
FUNCTION
P5.10
S9 Terminal function
0
◎
S9
FUNCTION
P5.11
S10 Terminal function
0
◎
S10
FUNCTION
P5.12
Switch signal filter
times
1~10
5
○
Sx FILTER
TIMES
P5.13
AI1 lower limit
0.00V~P5.15
0.00V
○
AI1 LOW
LIMIT
P5.14
AI1 lower limit
corresponding setting
-100.0%~100.0%
0.0%
○
AI1 LOW
SETTING
P5.15
AI1 upper limit
P5.13~10.00V
10.00V
○
AI1 UP LIMIT
P5.16
AI1 upper limit
corresponding setting
-100.0%~100.0%
100.0%
○
AI1 UP
SETTING
P5.17 AI1 filter time constant
0.00s~10.00s
0.10s
○
AI1 FILTER
TIME
P5.18
AI2 lower limit
0.00V~P5.20
0.00V
○
AI2 LOW
LIMIT
P5.19
AI2 lower limit
corresponding setting
-100.0%~100.0%
0.0%
○
AI2 LOW
SETTING
P5.20
AI2 upper limit
P5.18~10.00V
5.00V
○
AI2 UP LIMIT
P5.21
AI2 upper limit
corresponding setting
-100.0%~100.0%
100.0%
○
AI2 UP
SETTING
P5.22 AI2 filter time constant 0.00s~10.00s
0.10s
○
AI2 FILTER
TIME
P6 Group: Output terminals
P6.00
HDO output
selection
0: High-speed pulse
output
1: ON-OFF output
0
◎
HDO
SELECTION