CHV180 series frequency inverter special for elevator Appendix D
.136.
Function
Code
Name
Description
Factory
Setting
Mod
ify
LCD Display
model
RESISTOR
P2.12
Stator and rotor
inductance
0.1~6553.5mH
Depend on
model
○
LEAK
INDUCTOR
P2.13
Motor mutual
inductance
0.1~6553.5mH
Depend on
model
○
MUTUAL
INDUCTOR
P2.14
Motor current without
load
0.01~655.35A
Depend on
model
○
NO LOAD
CURR
P2.15~
P2.16
Reserved
0~65535
0
◎
RESERVE
FUNCTION
P3 Group: Vector control
P3.00
ASR low speed
roportional gain
0~100
20
○
ASR Kp1
P3.01
ASR low speed
integral time
0.01~10.00s
0.50s
○
ASR Ki1
P3.02
Speed detection low
speed filtrate times
0 ~ 9
3
○
SPEED
INSPECT
FILTER T1
P3.03
Switch low point
frequency
0.00Hz~P3.07
5.00Hz
○
ASR
SWITCHPOIN
T1
P3.04
ASR high speed
proportional gain
0~100
25
○
ASR Kp2
P3.05
ASR high speed
integral time
0.01~10.00s
1.00s
○
ASR Ki2
P3.06
Speed detection high
speed filtrate times
0~9
3
○
SPEED
INSPECT
FILTER T1
P3.07
Switch high point
frequency
P3.03~P0.04
10.00Hz
○
ASR
SWITCHPOIN
T2
P3.08
ACR proportional gain
P
0~65535
500
○
ACR P