42
inVENTer
®
iV12-Smart
®
/iV12-Smart
®
Corner ventilation system
•
Installation and operating instructions
►
Set heat recovery operating mode.
(See installation and operating instructions for the controller)
►
One fan is connected.
Supply air operation: LED ON.
Exhaust air operation: LED OFF.
Ö
Ö
LEDs switch between ON and OFF every 70 s.
►
Connect two to sixteen fans in pairs opposite each.
Supply air operation: LED ON.
Exhaust air operation: LED OFF.
Ö
Ö
LEDs switch between ON and OFF every 70 s.
Ö
Ö
Ventilation system is started.
5.12 fitting an inner cover
fitting the inner cover V-220x200
Requirements
Thermal accumulator/fan is mounted.
Initial settings are made.
►
Mount inner cover base plate (1) centrally to the
wall sleeve (2) on internal wall.
►
Insert screws (4) loose into the ixing
elements (3).
4
1
3
2
►
Align inner cover base plate (6) using a spirit
level (5).
6
5
assembly anD insTallaTion