25
inVENTer
®
iV12-Smart
®
/iV12-Smart
®
Corner ventilation system
•
Installation and operating instructions
assembly anD insTallaTion
►
Insert wall sleeve (1) from inside the room.
►
Ensure that there is a recess (2) at the
bottom left for the controller cable at an angle
of 45°.
or
►
Ensure that there is a recess (2) at the top
right for the controller cable at an angle
of 45°.
1
2
►
Align the position of the ixings (4) horizontally
using a spirit level (3).
3
4
►
Secure wall sleeve (5) with mounting wedges (6)
on the inside and outside.
►
Ensure that the wall sleeve (5) is aligned with
a fall of 1 – 2° to the external wall.
5
6
noTe
Contamination of the wall sleeve.
Damage to the insulation of the thermal accumulator!
► Before illing the gap with foam, insert protective discs.
noTe
Deformation of the wall sleeve.
Thermal accumulator cannot be installed!
► Insert thermal accumulator or suitable material before foaming the free space.