Afix sealing tape 9 mm (6) around the outer edge
of the weather protection hood base plate (7).
►
Ensure that the sealing tape (6) is at a
distance of 25 mm from the outer edge of the
weather protection hood base plate.
►
Ensure that the sealing tape (6) is affixed
on the external wall side to the weather
protection hood base plate (7).
6
7
10
►
Fit weather protection hood base plate (9) above
wall sleeve and mount on external wall.
►
Align weather protection hood base plate (9)
using a spirit level (8).
►
Mark out four holes (10).
►
Drill holes (10) with Ø 8 mm to a depth of min.
50 mm and insert wall plugs.
8
0
1
9
►
Secure weather protection hood base plate (11)
to the external wall using screws and
washers (12).
1
1
2
1
noTe
seal the joint between the weather protection hood base plate and facade.
Weather protection hood cover cannot be itted!
►
after
attaching the cover to the base plate, seal the joints between the weather protec-
tion hood cover and facade using non-shrink external sealing compound on both sides and
around the top edge.