35
inVENTer
®
iV12-Smart
®
/iV12-Smart
®
Corner ventilation system
•
Installation and operating instructions
Requirements
Wall sleeve is itted.
►
Afix end-stop tape 15 mm x 5 mm (1) on
external side around upper part of wall sleeve (2).
►
Ensure that the gap (3) in the end-stop tape
(1) is positioned at the bottom of the wall
sleeve (2).
1
2
3
►
Afix sealing tape 9 mm (4) around the opening of
the wall sleeve (5).
►
Ensure that the sealing tape (4) does not
protrude over the inside edge of the wall
sleeve opening.
5
4
►
Adjust lat tube installation length with sliding
sleeve (6).
►
Secure sliding sleeve (6) with watertight
adhesive tape (7) (adhesive tape not included as
part of standard delivery. Available as an optional
extra).
►
Ensure that flat tube installation length
corresponds to calculated installation length
(see section 5.8: Installing a corner flat
tube ‒Preparations prior to installation of flat
tube).
7
6
►
Fit lat tube (9) with wall installation opening on
protruding wall sleeve (8).
►
Align lat tube (9) with a fall of 1 – 2° to the
window embrasure.
8
1° - 2°
9
assembly anD insTallaTion