27
inVENTer
®
iV12-Smart
®
/iV12-Smart
®
Corner ventilation system
•
Installation and operating instructions
assembly anD insTallaTion
fitting the wall sleeve for the corner connection (Corner version)
TiP
Please observe a wall sleeve protrude on the exterior of 30 mm instead of 10 mm when itting
the wall sleeve.
Requirements
Controller cable in place.
Preparation set is available.
►
Determine precise wall thickness.
►
Add thickness of masonry (2) and interior
plaster (1) (if existing add render as well).
►
Ensure that the wall sleeve protrudes
30 mm into the insulation layer on the
outside.
1
2
1 ... 2°
30
TiP
For further mounting of the wall sleeve see section 5.6 Fitting the wall sleeve – wall sleeve
for weather protection hood. After completion of the external wall, trim wall sleeve with 30 mm
protruding up from the masonry.
►
Trim wall sleeve (3) with
30 mm
protruding up
from the masonry (exterior wall).
1
3
30
Ö
Ö
Wall sleeve is itted.