Interroll Roller Conveyor SH 1110
Maintenance and repair
48
Version 1.0 (06/2022) en
Translation of original operating instructions
Replacing the finger guard and PolyVee belt
2
1
3
4
1
Drive belt (PolyVee)
3
Top part of finger guard
2
Torx screw
4
Bottom part of finger guard
The finger guard protects against injuries as well as damage to the belt.
Ensure the drive is disconnected for the belt replacement.
WARNING
Risk of injury from crushing and electrocution
Installation and maintenance tasks on a conveyor system while it is in operation can cause
crushing and electric shock.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Requirement:
R
The module is shut down.
4
To do so, unscrew the screw (2), remove the top part (3) and pull the bottom part (4) out
from below.
4
Properly dispose of the old finger guard.
4
Loosen taper screw in roller and lift the roller.
4
Remove the drive belt (1) from the roller.
4
Properly dispose of the old belt.
4
Install new belt (1).
4
Tighten the roller with screws.
4
Insert the new finger guard: First, push in the bottom part (4) until it engages. This requires
access to the conveyor belt from below.