Troubleshooting
In case of a fault
DANGER
Danger to life from electrocution
4
Only perform maintenance and repair work after you have switched off power.
4
Faults on electrical equipment may be rectified only by a trained electrician!
4
Immediately power down the module and ensure that it cannot be started accidentally.
4
Remove material and objects that block the conveyor.
4
Before switching it on again, ensure that no persons are at risk.
4
Properly dispose of any gear oil that has leaked. Have the motor replaced by qualified
personnel, if necessary.
Troubleshooting
Fault
Cause
Remedy
Conveying goods jam
between the side guides
Conveying goods sit on the
module at an angle
Align conveying goods parallel
to the side guide
Center of gravity of the load is
not centered
Align the center of gravity of the
load
Transport process cannot
be started and RollerDrive
does not run
Main switch and/or control
system turned off (is the LED on
the MultiControl lit?)
Check the switch positions; if
necessary, turn on the main
switch and/or control
Supply line damaged
Check supply line
RollerDrive defective
Analyze error according to
RollerDrive EC5000 Operating
Instructions. Replace motor, if
necessary,
see "Electrical
Conveying goods are not
being transported
PolyVee drive belt defective
Replace the PolyVee drive belt,
see "Replacing the finger guard
and PolyVee belt", page 48
Transport weight too high
Observe maximum weight
MultiControl defective
Replace MultiControl,