S T A R G e n 2 R e c e i v e r U s e r ’ s G u i d e
Page 19 of 47
Alarm
The following settings are available in the ALARM submenus:
MODE
: OFF
=
Warning and Alarm are switched off.
: Warning Only
Upon an error condition the Warning light on the front
will be activated.
: RelayA
Upon an error condition, after the warning delay period
has passed, the Warning light on the front panel will
illuminate. It will remain illuminated until the alarm delay
period has passed, at which point the Warning LED will
turn off, the Alarm Led will flash red and relay A will
become active.
: RelayB
Upon an error condition, after the warning delay period
has passed, the Warning light on the front panel will
illuminate. It will remain illuminated until the alarm delay
period has passed, at which point the Warning LED will
turn off, the Alarm Led will flash red and relay B will
become active.
: RelayC
Upon an error condition after the warning delay period
has passed, the Warning light on the front panel will
illuminate. It will remain illuminated until the alarm delay
period has passed, at which point the Warning LED will
turn off, the Alarm Led will flash red and relay C will
become active.