P/N 1064130 (ML) • REV E • ISS 01JUL19
3 / 24
5
6
ATS120x V24 DGP
0-EXIT, Menu:
1-DGP status
0-EXIT, Menu:
Operating
*=-, #=+, 0-Exit
2-Input status
0-EXIT, Menu:
View Input State
Input No:
17, Normal, 113
*=-, #=+, 0-Exit
...
32, Open, 226
*=-, #=+, 0-Exit
3-DGP settings
0-EXIT, Menu:
1 DGP Address
*=Change, 0-Exit
Battery Load OFF
*=Change, 0-Exit
Mains Check ON
*=Change, 0-Exit
Extended mode
*=Change, 0-Exit
Static Outputs
*=Change, 0-Exit
4-Factory Reset
0-EXIT, Menu:
Factory Default
*=Yes,#=No:
EN: Installation Sheet
Description
The ATS1203(N)/ATS1204(N) provides zone expansion with 8
to 32 zones to ATS control panels with a built in power supply
of max. 3 A (total). Both the mains power supply and the
battery are monitored. The DGP also provides for 8 to 32
outputs occupying 2 DGP addresses when selected to support
more than 16 outputs.
The ATS1203(N)/ATS1204(N) functionality is similar to the
ATS1201.
Setup of the ATS1203(N)/ATS1204(N) is possible using the
built-in menu that can be accessed through Titan or the ATS
control panel menu 28.
Mains power connection
Use the mains connector terminal for connecting the mains-
supply. A fixed cable or a flexible mains leading to an earthed
mains outlet can be used. In case fixed wiring is used, insert a
dedicated circuit breaker in the power distribution network. In
all cases, the mains connection has to comply with local
regulations.