INSTALLING THE ACU
Configure Radiation Hazard/Blockage Zones
It is important to setup the radiation hazard or blockage zones for Intellian VSAT
communication systems. The ACU can be programmed with relative azimuth and
elevation sectors to create up to five zones where transmit power could endanger
personnel who are frequently in that area or blockage exists. Several indications are
providedwhen the antenna is within one of these zones.
RF Hazard Precautions
The antenna is designed to be used with radiation transmit equipment manufactured
by others. Exposure to RF radiation, including exposure associated with an improper
use of the transmit equipment, may be hazardous to persons close to the above
deck unit. Ensure safety of personnel who work on the system.
During transmission, ensure to keep the minimum safety distance. The recommended
minimum safety distance to the reflector on the focal line is about 15m, based on a
radiation level of 5mW/ cm2 that applies under occupational/controlled environment.
No hazard exists >20° below the antenna’s mounting plane
1.
“BLOCK” will be displayed on the ACU screen.
2.
Tracking continues as long as the signal level is greater than the predefined
threshold value. When the signal level drops below the threshold value the
antenna will wait the “Search Wait Time” parameter amount of time and re-target
the satellite last targeted. The antenna will continue to re-target the satellite until
the satellite is re-acquired and tracking can be resumed.
3.
A transmit inhibit output from the ACU will disable/mute the modem transmission.
Safe access from radiation hazard