128
Server System SR1630GP / SR1630HGP Service Guide
•
Do not access the inside of the power supply. There are no serviceable parts in the
power supply. Return to manufacturer for servicing.
•
Power down the chassis and disconnect all power cords before adding or replacing
any non hot-plug component.
•
When replacing a hot-plug power supply, unplug the power cord to the power supply
being replaced before removing the power supply from the chassis.
Caution:
If the compute module has been running, any installed processor(s) and heat sink(s) may
be hot. Unless you are adding or removing a hot-plug component, allow the compute
module to cool before opening the covers. To avoid the possibility of coming into contact
with hot component(s) during a hot-plug installation, be careful when removing or
installing the hot-plug component(s).
Caution:
To avoid injury do not contact moving fan blades. If your chassis is supplied with a guard
over the fan, do not operate the chassis without the fan guard in place.
Electrostatic Discharge (ESD)
Caution:
ESD can damage disk drives, boards, and other parts. We recommend that you perform
all procedures at an ESD workstation. If one is not available, provide some ESD
protection by wearing an antistatic wrist strap attached to chassis ground -- any
unpainted metal surface -- on your server when handling parts.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards
only by their edges. After removing a board from its protective wrapper or from the
server, place the board component side up on a grounded, static free surface. Use a
conductive foam pad if available but not the board wrapper. Do not slide board over any
surface.
Other Hazards
Battery Replacement
Caution:
There is the danger of explosion if the battery is incorrectly replaced. When replacing the
battery, use only the battery recommended by the equipment manufacturer.
Dispose of batteries according to local ordinances and regulations.
Do not attempt to recharge a battery.
Do not attempt to disassemble, puncture, or otherwise damage a battery.
Cooling and Airflow
Caution:
Carefully route cables as directed to minimize airflow blockage and cooling problems.
Summary of Contents for SR1630GP - Server System - 0 MB RAM
Page 4: ...iv Intel Server System SR1630GP SR1630HGP Service Guide...
Page 6: ...vi Intel Server System SR1630GP SR1630HGP Service Guide...
Page 12: ...xii Intel Server System SR1630GP SR1630HGP Service Guide...
Page 18: ...xviii Intel Server System SR1630GP SR1630HGP Service Guide...
Page 22: ...xxii Intel Server System SR1630GP SR1630HGP Service Guide...
Page 118: ...96 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 168: ...146 Intel Server System SR1630GP SR1630HGP Service Guide Intel Intel Intel Web UL...
Page 169: ...Intel Server System SR1630GP SR1630HGP Service Guide 147...
Page 170: ...148 Intel Server System SR1630GP SR1630HGP Service Guide ITE ITE 5V...
Page 171: ...Intel Server System SR1630GP SR1630HGP Service Guide 149...
Page 172: ...150 Intel Server System SR1630GP SR1630HGP Service Guide ESD ESD ESD ESD ESD...
Page 173: ...Intel Server System SR1630GP SR1630HGP Service Guide 151 1 2 3...
Page 174: ...152 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 188: ...166 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 192: ...170 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 196: ...174 Intel Server System SR1630GP SR1630HGP Service Guide...