Event
Filter
Number
Offset Mask
Events
1
Non-critical, critical and non-
recoverable
Temperature sensor out of range
2
Non-critical, critical and non-
recoverable
Voltage sensor out of range
3
Non-critical, critical and non-
recoverable
Fan failure
4
General chassis intrusion
Chassis intrusion (security violation)
5
Failure and predictive failure
Power supply failure
6
Uncorrectable ECC
BIOS
7
POST error
BIOS: POST code error
8
FRB2
Watchdog Timer expiration for FRB2
9
Policy Correction Time
Node Manager
10
Power down, power cycle, and reset
Watchdog timer
11
OEM system boot event
System restart (reboot)
12
Drive Failure, Predicted Failure
Hot Swap Controller
Additionally, the BMC supports the following PEF actions:
Power off
Power cycle
Reset
OEM action
Alerts
The “Diagnostic interrupt” action is not supported.
4.5.3.14
LAN Alerting
The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps),
and SMTP email alerts.
The BMC supports a minimum of four LAN alert destinations.
4.5.3.14.1
SNMP Platform Event Traps (PETs)
This feature enables a target system to send SNMP traps to a designated IP address by means
of LAN. These alerts are formatted per the
Intelligent Platform Management Interface
Specification Second Generation v2.0
. A MIB file associated with the traps is provided with the
BMC firmware to facilitate interpretation of the traps by external software.
The format of the MIB file is covered under RFC 2578.
4.5.3.15
Alert Policy Table
Associated with each PEF entry is an alert policy that determines which IPMI channel the alert