Appendix B: BMC Sensor Tables
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Revision 1.1
Intel order number G34153-003
134
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 1
Thermal Margin
(P1 Therm
Margin)
74h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 2
Thermal Margin
(P2 Therm
Margin)
75h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 3
Thermal Margin
(P3 Therm
Margin)
76h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 4
Thermal Margin
(P4 Therm
Margin)
77h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 1
Thermal
Control %
(
P1 Therm Ctrl
%
)
78h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
Trig
Offset
A
–
Processor 2
Thermal
Control %
(
P2 Therm Ctrl
%
)
79h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
Trig
Offset
A
–
Processor 3
Thermal
Control %
(
P3 Therm Ctrl
%
)
7Ah
Platform-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
Trig
Offset
A
–