Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSPlatform Management Overview
Revision 1.1
71
Intel order number G34153-003
If the BMC IP address source is DHCP, then the following behavior is seen:
If the BMC is first configured for DHCP (prior to enabling VLAN), when VLAN is enabled,
the BMC performs a discovery on the new VLAN in order to obtain a new BMC IP address.
If the BMC is configured for DHCP (before disabling VLAN), when VLAN is disabled, the
BMC performs a discovery on the LAN in order to obtain a new BMC IP address.
If the BMC IP address source is Static, then the following behavior is seen:
If the BMC is first configured for static (prior to enabling VLAN), when VLAN is enabled,
the BMC has the same IP address that was configured before. It is left to the management
application to configure a different IP address if that is not suitable for VLAN.
If the BMC is configure for static (prior to disabling VLAN), when VLAN is disabled, the
BMC has the same IP address that was configured before. It is left to the management
application to configure a different IP address if that is not suitable for LAN.
4.5.3.11
Secure Shell (SSH)
Secure Shell (SSH) connections are supported for one SMASH-CLP session to the BMC.
4.5.3.12
Serial-over-LAN (SOL 2.0)
The BMC supports IPMI 2.0 SOL.
IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standard
payload type (01h) over RMCP+.
Three commands are implemented for SOL 2.0 configuration.
1.
“Get SOL 2.0 Configuration Parameters”
and
“Set SOL 2.0 Configuration Parameters”:
These commands are used to get and set the values of the SOL configuration parameters.
The parameters are implemented on a per-channel basis.
2.
“Activating SOL”:
This command is not accepted by the BMC. It is sent by the BMC when
SOL is activated to notify a remote client of the switch to SOL.
3. Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is used,
it should be negotiated when the IPMI-over LAN session is established. Intel
®
Server Board
S2600IP SOL sessions are supported on serial port A (COM1). Intel
®
Workstation Board
S2600IP SOL sessions are supported on serial port B (COM2).
4.5.3.13
Platform Event Filter (PEF)
The BMC includes the ability to generate a selectable action, such as a system power-off or
reset, when a match occurs to one of a configurable set of events. This capability is called
Platform Event Filtering,
or PEF. One of the available PEF actions is to trigger the BMC to send
a LAN alert to one or more destinations.
The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table are pre-
configured (but may be changed by the user). The remaining entries are left blank, and may be
configured by the user.
Table 26. Factory Configured PEF Table Entries