Connector/Header Locations and Pin-outsIntel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
96
Revision 1.1
Intel order number G34153-003
Pin
Signal Name
Pin
Signal Name
29
GND
30
PRESENT#
6.4.3
TPM Connector
Table 46. TPM Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
Key
2
LPC_LAD<1>
3
LPC_LAD<0>
4
GND
5
IRQ_SERIAL
6
LPC_FRAME_N
7
P3V3
8
GND
9
RST_IBMC_NIC_N_R2
10
CLK_33M_TPM
11
LPC_LAD<3>
12
GND
13
GND
14
LPC_LAD<2>
6.4.4
PMBus* Connector
Table 47. PMBus* Connector Pin-out
Pin
Signal name
1
SMB_PMBUS_CLK_R
2
SMB_PMBUS_DATA_R
3
IRQ_SML1_PMBUS_ALERT_RC_N
4
GND
5
P3V3
6.4.5
Chassis Intrusion Header
The server board includes a 2-pin chassis intrusion header which can be used when the chassis
is configured with a chassis intrusion switch. The header has the following pin-out.
Table 48. Chassis Intrusion Header Pin-out
Header State
Description
Pins 1 and 2 closed
FM_INTRUDER_HDR_N is pulled HIGH. Chassis cover is closed.
Pins 1 and 2 open
FM_INTRUDER_HDR_N is pulled LOW. Chassis cover is removed.
6.4.6
IPMB Connector
Table 49. IPMB Connector Pin-out
Pin
Signal Name
1
SMB_IPMB_5VSTBY_DATA
2
GND
3
SMB_IPMB_5VSTBY_CLK
4
P5V_STBY
6.5 FAN Connectors
The server board provides support for nine fans. Seven of them are system cooling fans, two of
them are CPU fans.
Summary of Contents for S2600IP
Page 14: ......