![Intel S2600IP Technical Product Specification Download Page 140](http://html1.mh-extra.com/html/intel/s2600ip/s2600ip_technical-product-specification_2072184140.webp)
Appendix B: BMC Sensor Tables
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Revision 1.1
Intel order number G34153-003
126
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
System Event
Log
(System Event
Log)
07h
All
Event Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK
As
–
Trig
Offset
A
X
System Event
(System Event)
08h
All
System Event
12h
Sensor
Specific
6Fh
02 -
Undetermined
system H/W
failure
04
– PEF action
Fatal
OK
As and De
As
-
Trig
Offset
A
X
Button Sensor
(Button)
09h
All
Button/Switch
14h
Sensor
Specific
6Fh
00
– Power Button
02
– Reset Button
OK
AS
_
Trig
Offset
A
X
BMC Watchdog
0Ah
All
Mgmt System
Health
28h
Digital Discrete
03h
01
– State
Asserted
Degraded
As
–
Trig
Offset
A
-
Voltage
Regulator
Watchdog
(VR Watchdog)
0Bh
All
Voltage
02h
Digital Discrete
03h
01
– State
Asserted
Fatal
As and De
–
Trig
Offset
M
X
Fan
Redundancy
1
(Fan
Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully
redundant
OK
As and De
–
Trig
Offset
A
–
01 - Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
Sufficient
resources.
Transition from
redundant
Degraded
Summary of Contents for S2600IP