Multiport Mini-SAS/SATA Connectors
The board includes two 40-pin high density multiport mini-SAS/SATA connectors. On the board,
these connectors are labeled as “SCU0 port(0-3)” supporting the chipset embedded SCU0
controller, and “SCU1 Port(4-7)”, supporting the embedded SCU1 controller. Both connectors
can support up to four SATA or SAS ports each. By default,
only the connector labeled “SCU0
Port(0-
3)” is enabled and has support for up to four SATA ports capable. The connector labeled
“SCU1 Port(4-7)” is only enabled when an optional 8-port SAS or SATA Intel
®
RAID C600
Upgrade Key is installed. The following tables provide the pin-out for each connector.
Table 37. Multiport SAS/SATA Connector Pin-out ("SCU_0 (0-3)")
Pin
Signal name
Pin
Signal name
A1
GROUND
B1
GROUND
A2
SAS0_RX_C_DP
B2
SAS0_TX_C_DP
A3
SAS0_RX_C_DN
B3
SAS0_TX_C_DN
A4
GROUND
B4
GROUND
A5
SAS1_RX_C_DP
B5
SAS1_TX_C_DP
A6
SAS1_RX_C_DN
B6
SAS1_TX_C_DN
A7
GROUND
B7
GROUND
A8
TP_SAS1_BACKPLANE_TYPE
B8
SGPIO_SAS1_CLOCK
A9
GROUND
B9
SGPIO_SAS1_LOAD
A10
SGPIO_SAS1_DATAOUT
B10
GROUND
A11
SGPIO_SAS1_DATAIN
B11
PD_SAS1_CONTROLLER_TYPE
A12
GROUND
B12
GROUND
A13
SAS2_RX_C_DP
B13
SAS2_TX_C_DP
A14
SAS2_RX_C_DN
B14
SAS2_TX_C_DN
A15
GROUND
B15
GROUND
A16
SAS3_RX_C_DP
B16
SAS3_TX_C_DP
A17
SAS3_RX_C_DN
B17
SAS3_TX_C_DN
A18
GROUND
B18
GROUND
MTH1
GROUND
MTH5
GROUND
MTH2
GROUND
MTH6
GROUND
MTH3
GROUND
MTH7
GROUND
MTH4
GROUND
MTH8
GROUND
Table 38. Multiport SAS/SATA Connector Pin-out ("SCU_1 (4-7)")
Pin
Signal name
Pin
Signal name
A1
GROUND
B1
GROUND
A2
SAS4_RX_C_DP
B2
SAS4_TX_C_DP
A3
SAS4_RX_C_DN
B3
SAS4_TX_C_DN
A4
GROUND
B4
GROUND
A5
SAS5_RX_C_DP
B5
SAS5_TX_C_DP
A6
SAS5_RX_C_DN
B6
SAS5_TX_C_DN
A7
GROUND
B7
GROUND
A8
TP_SAS2_BACKPLANE_TYPE
B8
SGPIO_SAS2_CLOCK
A9
GROUND
B9
SGPIO_SAS2_LOAD
A10
SGPIO_SAS2_DATAOUT
B10
GROUND
A11
SGPIO_SAS2_DATAIN
B11
PD_SAS2_CONTROLLER_TYPE
A12
GROUND
B12
GROUND
A13
SAS6_RX_C_DP
B13
SAS6_TX_C_DP