88
‑
Figure 3‑20 Recommended power cables
Observe national or regional regulations when selecting cable dimensions. The IEC
cable must meet the following requirements:
●
Complying with standards EN 60204‑1 and IEC 60364‑5‑52
●
PVC cable with copper conductors
●
Allowing the cable surface temperature to be lower than or equal to 70℃ under an
ambient temperature of 40℃ (When the ambient temperature exceeds 40℃,
contact Inovance.)
Requirements for UL cable selection are described in
Note
If the recommended cable specifications for peripheral devices or optional parts exceed the
applicable cable specification range, contact Inovance.
3.5.4 Wiring of the Power Supply
●
Single‑phase 220 V models: SV660PS1R6I, SV660PS2R8I, SV660PS5R5I,
SV660PS7R6I, and SV660PS012
Summary of Contents for SV660P Series
Page 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Page 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Page 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Page 113: ...Wiring 112 Scheme 2 Using the external resistor...
Page 144: ...Maintenance 143...