58
‑
For the sake of safety, install a residual current device (RCD) to provide protections
against overload and short circuit or a specialized RCD to protect the grounding
cable.
●
Do not start or stop the motor by using the electromagnetic contactor. As a high‑
inductance device, the motor may generate high voltages instantaneously, which
may break down the contactor.
●
When connecting an external power supply to the control circuit or a 24 VDC
power supply, pay attention to the power capacity as insufficient power capacity
will lead to insufficient supply current, resulting in failure of the servo drive or the
brake. This is especially true when the power supply is used to power up multiple
servo drives or brakes. The brake must be powered up by a 24 VDC power supply
that matches the motor model and meets the brake power requirements.
Note
[1] CN3 and CN4 are identical communication interfaces with the same pin assignment, and
either can be used.
Observe the following precautions when connecting the external regenerative resistor:
●
Remove the jumper between P⊕ and D before using the external regenerative
resistor. Failure to comply will result in overcurrent and damage the braking
transistor.
●
Do not connect the external regenerative resistor to the positive or negative pole
of the bus directly. Failure to comply will damage the servo drive or cause a fire.
●
Select a resistor with resistance higher than the minimum permissible value.
Failure to comply will result in Er.201 (Overcurrent) or damage the servo drive.
●
Make sure parameters H02‑25 (Regenerative resistor setting), H02‑26 (Power of
external regenerative resistor) and H02‑27 (Resistance of external regenerative
resistor) are set properly before operating the servo drive.
●
Install the external regenerative resistor on an incombustible object such as a
metal.
Summary of Contents for SV660P Series
Page 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Page 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Page 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Page 113: ...Wiring 112 Scheme 2 Using the external resistor...
Page 144: ...Maintenance 143...