38
‑
2.2.2 Installation Environment
Item
Requirement
Altitude
The maximum altitude is 5000 m.
Derating is not required for altitudes above 1000 m.
For altitudes above 1000 m, derate 1% for every additional 100 m.
For altitudes above 2000 m, contact Inovance.
Ambient
temperature
0°C to 40℃ (non‑freezing)
Storage
temperature
‑20°C to +60°C (Peak temperature: 80°C for 72 hours)
Ambient
humidity
20%
–
80% RH (without condensation)
Storage humidity 20%
–
90% RH (without condensation)
Vibration
Below 49 m/s
2
Shock
Below 490 m/s
2
IP rating
After wiring is done, the overall IP rating of the motor is as follows:
IP67 (shaft opening excluded, with power cables and encoder
connectors installed properly)
Installation
location
●
Install the servo motor in a place free from corrosive and
inflammable gases and combustible materials, such as the
hydrogen sulfide, chlorine, ammonia, sulphur gas, chloridize gas,
acid, soda and salt.
●
Use the servo motor with oil seal when the motor is to be used in
a place with grinding fluid, oil mist, iron powders or cuttings.
●
Install the servo motor away from heating sources such as a
heating stove.
●
Do not use the servo motor in an enclosed environment.
Running in an enclosed environment will lead to motor over‑
temperature, which shortens its service life.
Summary of Contents for SV660P Series
Page 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Page 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Page 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Page 113: ...Wiring 112 Scheme 2 Using the external resistor...
Page 144: ...Maintenance 143...