![Inovance SV660P Series Hardware Manual Download Page 60](http://html1.mh-extra.com/html/inovance/sv660p-series/sv660p-series_hardware-manual_2064768060.webp)
‑59‑
Figure 3‑2 Wiring example of a three‑phase 220 V system
●
The servo drive is directly connected to an industrial power supply, with no
isolation such as a transformer. A fuse or circuit breaker therefore must be
connected to the input power supply to prevent electric shock in the servo system.
For the sake of safety, install a residual current device (RCD) to provide protections
against overload and short circuit or a specialized RCD to protect the grounding
cable.
●
Do not start or stop the motor by using the electromagnetic contactor. As a high‑
inductance device, the motor may generate high voltages instantaneously, which
may break down the contactor.
Summary of Contents for SV660P Series
Page 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Page 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Page 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Page 113: ...Wiring 112 Scheme 2 Using the external resistor...
Page 144: ...Maintenance 143...