5 Troubleshooting
5
- 68 -
Function
Code
Parameter Name
Setting Range
Unit Default ET Pro CM
H03-13 DI6 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-14 DI7 function selection
0 to 37
-
3
St
Ru
-
H03-15 DI7 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-16 DI8 function selection
0 to 37
-
31
St
Ru
-
H03-17 DI8 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-18 DI9 function selection
0 to 37
-
0
St
Ru
-
H03-19 DI9 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-34 DI function (active after
power-on) allocation 3
0 to 0xFFFF
Bit0: FunIN.33; Bit1: FunIN.34
……Bit15: FunIN.48
-
0
Po Ru
-
H03-35 DI function (active after
power-on) allocation 4
0 to 0xFFFF
Bit0: FunIN.49; Bit1:FunIN.50
……Bit15: FunIN.64
-
0
Po Ru
-
H03-50 AI1 offset
-5000 to 5000
mV
0
Im
Ru
-
H03-51
AI1 filter time constant
0 to 655.35
ms
2.00
Im
Ru
-
H03-53 AI1 dead zone
0 to 1000.0
mV
10.0
Im
Ru
-
H03-54 AI1 zero drift
-500.0 to 500.0
mV
0.0
Im
Ru
-
H03-55 AI2 offset
-5000 to 5000
mV
0
Im
Ru
-
H03-56
AI2 filter time constant
0 to 655.35
ms
2.00
Im
Ru
-
H03-58 AI2 dead zone
0 to 1000.0
mV
10.0
Im
Ru
-
H03-59 AI2 zero drift
-500.0 to 500.0
mV
0.0
Im
Ru
-
H03-80 Speed corresponding to 10
V
0 to 9000
RPM 3000
RPM
Im
St
-
H03-81 Torque corresponding to
10 V
1.00 to 8.00 times of rated torque
1.00 1.00
Im
St
-