5 Troubleshooting
5
- 67 -
Function
Code
Parameter Name
Setting Range
Unit Default ET Pro CM
H02-39 Maximum braking current at
short-circuit
0 to 3000
0.1% 1000
Im
St
S
Group H03: Input Terminal Parameters
Function
Code
Parameter Name
Setting Range
Unit Default ET Pro CM
H03-00 DI function (active after
power-on) allocation 1
0–0xFFFF
Bit0: FunIN.1; Bit1: FunIN.2
……Bit15: FunIN.16
-
0
Po Ru
-
H03-01 DI function (active after
power-on) allocation 2
0–0xFFFF
Bit0: FunIN.17; Bit1: FunIN.18
……Bit15: FunIN.32
-
0
Po Ru
-
H03-02 DI1 function selection
0 to 37
-
14
St
Ru
-
H03-03 DI1 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-04 DI2 function selection
0 to 37
-
15
St
Ru
-
H03-05 DI2 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-06 DI3 function selection
0 to 37
-
13
St
Ru
-
H03-07 DI3 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-08 DI4 function selection
0 to 37
-
2
St
Ru
-
H03-09 DI4 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-10 DI5 function selection
0 to 37
-
1
St
Ru
-
H03-11 DI5 logic selection
Input polarity: 0 to 4
0: Low level valid
1: High level valid
2: Rising edge valid
3: Falling edge valid
4: Rising edge and falling edge both valid
-
0
St
Ru
-
H03-12 DI6 function selection
0 to 37
-
12
St
Ru
-
Summary of Contents for IS650P Series
Page 1: ......
Page 101: ...100 Revision History Date Version Change Description March 2017 A00 First issue...