OVERVIEW

The following procedure is a supplement to other documentation available 
for the G+ Mini drive. This will guide the user in proper installation and setup 
of the system.

When installing the system, be sure to follow good wiring practices and 
follow all applicable electrical codes. Ensure that the mounting of all 
components are secure and the environment, such as excessive moisture, 
poor ventilation, etc., will not cause system degradation.

Read this document, provided with the G+ Mini, thoroughly before 
attempting installation. Refer to the technical manual, as needed, available 
at: 
http://www.magnetekmh.com/Material%20Handling/Product%20Manuals

Step 1

Connect Motor and Line Power

Figure 1 shows the electrical connections for the input power and motor 
terminals on the G+ Mini drive. Make the appropriate connections, with 
power turned off. Follow good wiring practices and follow all applicable 
electrical codes. Ensure the equipment is properly grounded, as shown.

Figure 1: Input Power and Output Motor Connections

DANGER! DANGEROUS VOLTAGES ARE PRESENT WHEN DRIVE 
IS ON. Improper wiring can cause bodily harm and damage to the 
equipment. Before applying power to the G+ Mini, ensure that all 
protective covers are fastened and all wiring connections are 
secure. After power has been turned OFF, wait at least 5 
minutes until the charge indicator extinguishes completely before 
touching any wiring, circuit boards, or components.

WARNING: DO NOT CONNECT ANY OF THE FOLLOWING 
TERMINALS TO EARTH GROUND.

Step 2

Typical Connection Diagram

This step shows a typical wiring diagram and connection points for the G+ Mini. 
Wiring connections should only be made by trained and authorized personnel 
when power to the drive is turned off.

*

24VDC interface is standard. 120VAC, 42-48VAC, and 24VAC is optional.

** Optional P3S2-OUT2 card provides two 240 VAC, 1.5 Amp solid-state relay outputs 

(panel-mounted).

*** In accordance with UL508C, EN954-1 Safety Category 3, and EN61508, SIL2.

Figure 2: Typical Connection Diagram

Step 3

Changing Parameters and Monitoring the G+ Mini

This step shows how to access and modify a G+ Mini parameter as well as how to 
monitor G+ Mini signals such as output frequency and motor current.

Make sure all protective covers have been re-attached and power is turned on. 
DO NOT RUN THE MOTOR.

Accessing Parameter Menu & Changing Parameters

Figure 3: G+ Mini Digital Operator Power-up State

Press 

 four times until the digital operator shows the parameter menu (PAr) 

then press 

.

Figure 4: Select Parameter Value

Press 

 to select the digit you would like to change. Next use 

 and 

 to 

select the parameter group, sub-group, or number.

Figure 5: Select Parameter

Modify the parameter value using 

 and 

. Press 

 to save the new 

value.

Figure 6: Change Parameter Value

Press ESC several times to return to the main display.

P.O. Box 13615
Milwaukee, WI 53213
Toll-Free Phone: 800-288-8178
Toll-Free Fax: 800-298-3503